Search results for " optical coherence tomography"
showing 10 items of 15 documents
Retinal Thickness and Microvascular Pattern in Early Parkinson's Disease.
2020
A thinning of intraretinal layers has been previously described in Parkinson's disease (PD) patients compared to healthy controls (HCs). Few studies evaluated the possible correlation between retinal thickness and retinal microvascularization. Thus, here we assessed the thickness of retinal layers and microvascular pattern in early PD patients and HCs, using, respectively, spectral-domain optical coherence tomography (SD-OCT) and SD-OCT-angiography (SD-OCT-A), and more interestingly, we evaluated a possible correlation between retinal thickness and microvascular pattern. Patients fulfilling criteria for clinically established/clinically probable PD and HCs were enrolled. Exclusion criteria …
The Usefulness of Optical Coherence Tomography in Disease Progression Monitoring in Younger Patients with Relapsing-Remitting Multiple Sclerosis: A S…
2022
The purpose of the study was to assess the usefulness of optical coherence tomography (OCT) in the detection of the neurodegenerative process in younger patients with multiple sclerosis (MS). The study group consisted of 61 patients with a relapsing remitting course of MS (mean age 36.4 ± 6.7 years) divided into two groups: short (≤5 years) and long (>10 years) disease duration. OCT, P300 evoked potential, Montreal Cognitive Assessment, and performance subtests (Picture Completion and Digit Symbol) of the Wechsler Adult Intelligence Scale were performed in all patients. Mean values of most parameters assessed in OCT (pRNFL Total, pRNFL Inferior, pRNFL Superior, pRNFL Temporalis, mRNFL, G…
Intravitreal therapies for non-neovascular age-related macular degeneration with intraretinal or subretinal fluid
2017
OBJECTIVE: To evaluate the efficacy of intravitreal therapies in cases of atrophic age-related macular degeneration (AMD) with subretinal or intraretinal fluid. METHODS: A retrospective review was made of the clinical charts of patients diagnosed with atrophic AMD with subretinal or intraretinal fluid. Fundus photographs and spectral-domain optical coherence tomography images were examined, and an analysis was made on the presence of fluid and its density. Neovascularisation was ruled out by fluorescein and/or indocyanine green angiography. RESULTS: The study included 14 eyes from 13 patients with a mean age of 72.64 years and a mean follow-up of 80.5 weeks. Intraretinal fluid was observed …
Dexamethasone for unresponsive diabetic macular oedema: optical coherence tomography biomarkers
2019
Purpose: To analyse the effects of intravitreal dexamethasone implant (DEX) in patients with diabetic macular oedema (DME) unresponsive to ranibizumab treatment, in relation to the inflammatory optical coherence tomography (OCT) retinal features, subfoveal neuroretinal detachment (SND) and hyperreflective retinal spots (HRS). Methods: Patients with DME poorly responsive to three injections of ranibizumab were treated with DEX. Best-corrected visual acuity (BCVA) and central macula thickness (CMT, measured by Spectralis SD-OCT) were assessed at baseline and at 1, 3, and 6 months. Results: Overall, 44 eyes were included in the study. In the whole group, mean BCVA (baseline 51.5 ± 8.3 letters)…
Chromatic-achromatic perimetry in four clinic cases: Glaucoma and diabetes
2015
Color perimetry has interesting clinical application for the diagnosis and detection of certain eye conditions, due to the variations that certain diseases can cause in chromatic thresholds, both in the red-green (RG) and the blue-yellow (BY) pathways.[1,2,3,4] The separate study of the visual function of both the chromatic and achromatic mechanisms could be more efficient in detecting sensitivity variations, and such variations would not be obscured by the intrusion of other mechanisms. Currently, the supply of conventional perimeters that are capable of performing a chromatic perimetry test is very limited and with reduced options regarding the possibility of choosing the physical charact…
Immune-Mediated Desquamative Gingivitis and Optical Coherence Tomography Diagnostic Patterns: Clinical Implication from a Systematic Review
2021
Desquamative Gingivitis (DG) comprises heterogeneous clinical manifestations of numerous immune-mediated muco-cutaneous diseases. Optical Coherence Tomography (OCT) has been proposed as a valuable diagnostic support even if, to date, there are no standardized OCT-diagnostic patterns applicable to DGs. A systematic review was performed to detect existing data on in vivo OCT diagnostic patterns of the most common immune-mediated DGs (i.e., pemphigus vulgaris, mucous membrane pemphigoid and oral lichen planus). It has been found that OCT exhibits specific patterns that address the diagnosis of DG by pemphigus vulgaris (i.e., intraepithelial unilocular blister, reduced epithelial thickness, pre…
NEURODEGENERATION IN MULTIPLE SCLEROSIS: COMPARISON BETWEEN CLINICAL, NEUROPSYCHOLOGICAL, MRI,AND OPTICAL COHERENCE TOMOGRAPHY PARAMETERS
2015
BACKGROUND AND OBJECTIVE Optical Coherence Tomography (OCT) enables rapid, non-invasive in vivo measurement of retinal nerve fiber layer (RNFL) thickness, reflecting axonal density within the optic nerve. There is still lack of concordance about the use of OCT in clinical routine as a surrogate measure of brain atrophy. Objective: To investigate the role of OCT as possible predictor of disability, cognitive impairment and neurodegeneration in Multiple Sclerosis (MS). MATERIAL AND METHODS We recruited patients affected by MS according to validated criteria at the Neurological Department of the University of Palermo. Patients performed Stratus OCT- 3 Zeiss to assess RNFL and GCS measurements.…
Rheological and Flocculation Analysis of Microfibrillated Cellulose Suspension Using Optical Coherence Tomography
2018
A sub-micron resolution optical coherence tomography device was used together with a pipe rheometer to analyze the rheology and flocculation dynamics of a 0.5% microfibrillated cellulose (MFC) suspension. The bulk behavior of the MFC suspension showed typical shear thinning (power-law) behavior. This was reflected in a monotonously decreasing floc size when the shear stress exceeded the yield stress of the suspension. The quantitative viscous behavior of the MFC suspension changed abruptly at the wall shear stress of 10 Pa, which was reflected in a simultaneous abrupt drop of the floc size. The flocs were strongly elongated with low shear stresses. With the highest shear stresses, the flocs…
Early OCTA Changes of Type 3 Macular Neovascularization Following Brolucizumab Intravitreal Injections
2022
Background and Objectives: Brolucizumab is a novel anti-vascular endothelial growth factor (VEGF), whose efficacy has been shown in the Hawk and Harrier phase 3 clinical studies. The goal of the present case series is to report initial results of brolucizumab intravitreal injections (IVI) on type 3 neovascularization in neovascular age-related macular degeneration (nAMD), evaluated by optical coherence tomography angiography (OCTA). Materials and Methods: This is a bicentric retrospective case series. Patients with newly diagnosed type 3 MNV treated with brolucizumab IVI and at least 6 months follow-up were enrolled. OCTA en face images and B-scans were analyzed for lesions at baseline, 1 m…
Relationship of choroidal thickness with pulsatile hemodynamics in essential hypertensive patients
2021
Controversy exists about the association of choroidal thickness (CTh) with blood pressure (BP) values. There is some evidence suggesting that central hemodynamics changes are associated with microvascular disease. Our study was aimed to assess the relationships between CTh and clinic and 24-h BP and between CTh and estimated 24-h aortic pulse pressure (aPP), 24-h aortic systolic BP (aSBP), and 24-h aortic augmentation index (aAIx) in a group of hypertensive patients. We enrolled 158 hypertensive subjects (mean age 48 ± 13 years) all of which underwent evaluation of the choroidal district by Swept-Source optical coherence tomography (SS-OCT) and 24-h BP monitoring, in order to measure periph…